Mandan Building & Design Criteria
City of Mandan Codes
The following codes are currently enforced by the City of Mandan:
- 2021 International Building Code (IBC)
- 2021 International Residential Code (IRC)
- 2021 International Fire Code (IFC)
- 2021 International Fuel Gas Code (IFC)
- 2021 International Mechanical Code (IMC)
- 2021 International Energy Conservation Code (IECC)
- 2021 International Existing Building Code (IEBC)
- ICC ANSI A117.1 2017 (All new bathrooms will need to meet these requirements)
- National Electrical Code and the North Dakota State Wiring Standards adopted by the North Dakota State Electrical Board
- Uniform Plumbing Code and the North Dakota State Plumbing Standards adopted by the North Dakota State Plumbing Board
IRC Climatic and Geographic Design Criteria
- Ground snow load: 40 psf
- Wind Design speed: 115 mph
- Wind Design topographic effects: NO
- Wind Design special wind region: NO
- Wind Design wind-borne debris zone: NO
- Seismic Design Criteria: Zone A
- Subject to Damage From weathering: Severe
- Subject to Damage from frost depth: 4 feet
- Subject to Damage from termite: NO
- Winter Design Temp: -19
- Ice Barrier Underlayment Required: YES
- Flood Hazards: Current FIRM adopted 2007.
- Air Freezing Index: 4000
- Mean Annual Temp: 42 degrees (F)
IRC Energy Efficiency Building Thermal Envelope Requirements
- Climate Zone: 6A
- Fenestration U-factor: 0.30 Maximum
- Skylight U-Factor: 0.55 Maximum
- Ceiling R-Value: 49 Minimum
- Wood Frame Wall R-Value: 21 or 13+5 Minimum
- Mass Wall R-Value: 15/20 Minimum
- Basement Wall R-Value: 10/13 Minimum
- Slab R-Value and Depth: 10, 4ft Minimum
- Crawl Space Wall R-Value: 10/13 Minimum